Festo Кабели и принадлежности User Manual
Page 354
7. Description of the commands
7−88
Festo P.BE−SPC200−EN en 0901d
#TN
Test single−bit operand for 0−signal
ć permitted in operating modes: Start/Stop
Nn #TN
Fn
Flag with number Fn
n = 0 ... 63
Fn
Axis status flag
1)
n = 64 ... 127
In.n
Permitted inputs: all existing inputs
n.n = 0.0 ... 13.15
Qn.n
Permitted outputs: all existing outputs
n.n = 0.0 ... 13.15
b n Record number n = 0 ... 999 number> Rn Record number saved in register Rn n = 0 ... 99 Effect A branch is made to the specified NC record if the single−bit operand supplies a Example N030 #TNI0.0 30 ;Wait until I0.0 supplies a 0−signal Remark See also under Test register" 1) This syntax is only available as from operating system version 4.63. It is not supported by the Axis status flag Flag number of the axis Name Meaning X Y Z U REF Reference set 64 65 66 67 MC Motion Complete 72 73 74 75 TOL Axis in the tolerance 80 81 82 83 MOV The axis moves 84 85 86 87
0−signal. Otherwise the following NC record will be processed.
Permitted operands are all single−bit operands. See also chapter 7.2.
control panel.
window