beautypg.com

2 addressing the control signals, Addressing the control signals – Festo Кабели и принадлежности User Manual

Page 282

background image

7. Description of the commands

7−16

Festo P.BE−SPC200−EN en 0901d

7.2.2

Addressing the control signals

Record Select mode

Control sigĆ
nal

I/O module
addresses

Address with
fieldbus

Description

ENABLE

I0.9

I10.0

Controller enable (1 = controller enabled)

RESET

I0.8

I10.1

Reset programs (in conjunction with
STOP=0)

STOP

I0.7

I10.2

Stop positioning task (0 = stopped)

CLK_A/B

I0.6 / I0.5

I10.3 / I10.4

Start NC record from program A/B

RECBIT1...5

I0.0 ... I0.4

ć

Bits for NC record number: RECBIT1 for2^0
etc. (record bit)

RECBIT...

ć

I11.0 ... I11.15

RECBIT... with control via a field bus module
as 2−byte value from 0 to 999, see manual
on the field bus module.

READY

Q0.7

Q10.0

System ready to operate

ACK_A/B

Q0.6 / Q0.5

Q10.1 / Q10.2

Task accepted for program A/B (acknowlĆ
edge)

RC_A/B

Q0.4 / Q0.3

Q10.3 / Q10.4

NC record concluded by program A/B (reĆ
cord complete)