6. Operating the SPC200 with the control panel
6−25
Festo P.BE−SPC200−EN en 0901d
Menu CONFIG. SYSTEM (Configure system)
OPERATING MODE
START/STOP
Operating mode
START/STOP
; Start/Stop mode
RECORD SELECT
; Record select mode
The operating mode defines how the sequence control of the SPC200
should function. Explanations of the operating modes can be found in
chapter 5.
DEFINE TASKS
TA:P00
Define starting programs
Tn
; Task number TA, TB
Pn
; Program number − −/0...99
P− − for "no starting program defined"
If the cursor is positioned at P, you can switch between P00 and P− − for
task B.
An SPC200 can control two work stations. It thereby supports the
coordinated and the autonomous operation of the two axes. In coordiĆ
nated mode the possibility of parallel program processing is not used.
Only one starting program is defined (an active task). This controls both
work stations. In autonomous mode two starting programs (two active
tasks) are defined. Each starting program controls a different work staĆ
tion. Further information on the coordinated and autonomous modes
can be found in chapter 7.1.1.
Summary: Set parameters
Purpose
Press ...
Ĉ Confirm current parameter selection
Ĉ Accept setting made
Enter
Ĉ Position cursor on axis identifier or
parameter value or figure
{ }
Ĉ Modify the setting at the current cursor
position (increase/decrease figure value)
v V
Ĉ Abort entries
Ĉ Switch back to next higher menu level
Esc