8. Diagnosis and error treatment

8−26

Festo P.BE−SPC200−EN en 0901d

Fault class 6:

Fault in positioning task or identification travel

Fault
stage

Eliminating faults

Operating status / fault explanation

Fault
message

C

nnn10x06

Controller is inactive, as enable signal for
first commissioning or after movement test is
missing or the configuration is faulty.

Only with stepping motor axis:
Ĉ No Ready signal from the power controller

·

Generate rising edge at
ENABLE input or check conĆ
troller, axis and application
data

·

Correct fault on stepping
motor controller

nnn11x06

Command is not supported by this axis type:
With pneumatic axes:
Ĉ Command Reference travel (G74)
With electric axes:
Ĉ Activate analogue input in modes 0 and 1

(M10)

Ĉ Command M39

·

Correct NC program

nnn12x06

Reference position for this axis unknown

·

Carry out reference travel

nnn13x06

Violation of software end positions with
command M39

·

Check software end posiĆ
tions and variable value with
command M39; if necessary
correct NC program

nnn14x06

Violation of speed limit value (M41) with
M39

·

Check speed limit value and
variable value with comĆ
mand M39; if necessary
correct NC program

nnn15x06
...
nnn19x06

Reserved

zzz = Additional information
yy = Fault number
x

= Axis identifier (0 = fault is not axis−related)

nnn = NC record number of the accessing NC command