Festo Кабели и принадлежности User Manual
Page 382
8. Diagnosis and error treatment
8−26
Festo P.BE−SPC200−EN en 0901d
Fault class 6:
Fault in positioning task or identification travel
Fault
stage
Eliminating faults
Operating status / fault explanation
Fault
message
C
nnn10x06
Controller is inactive, as enable signal for
first commissioning or after movement test is
missing or the configuration is faulty.
Only with stepping motor axis:
Ĉ No Ready signal from the power controller
·
Generate rising edge at
ENABLE input or check conĆ
troller, axis and application
data
·
Correct fault on stepping
motor controller
nnn11x06
Command is not supported by this axis type:
With pneumatic axes:
Ĉ Command Reference travel (G74)
With electric axes:
Ĉ Activate analogue input in modes 0 and 1
(M10)
Ĉ Command M39
·
Correct NC program
nnn12x06
Reference position for this axis unknown
·
Carry out reference travel
nnn13x06
Violation of software end positions with
command M39
·
Check software end posiĆ
tions and variable value with
command M39; if necessary
correct NC program
nnn14x06
Violation of speed limit value (M41) with
M39
·
Check speed limit value and
variable value with comĆ
mand M39; if necessary
correct NC program
nnn15x06
...
nnn19x06
Reserved
zzz = Additional information
yy = Fault number
x
= Axis identifier (0 = fault is not axis−related)
nnn = NC record number of the accessing NC command