beautypg.com

Festo Кабели и принадлежности User Manual

Page 366

background image

8. Diagnosis and error treatment

8−10

Festo P.BE−SPC200−EN en 0901d

Fault class

The fault class reflects the type of fault which has occurred
(e.g. hardware fault, configuration fault etc.) as well as the
time the fault occurred. If the SPC200 is ready for communiĆ
cation, the ERROR−LED will flash according to the fault class.

Fault time

Fault
class

Description

Initialization phase

1

Faults in initializing the components and modules

2

Reserved

3

User data damaged

Operating phase

4

Hardware fault in the operating phase

5

Sequence control fault (e.g. due to fault in the NC program)

Operating or commisĆ
sioning phase

6

Fault in positioning task or identification travel

Commissioning phase

7

Fault in pre−parametrizing

8

NC Editor, Upload/download or operation execution fault

9

Trace fault