beautypg.com

Festo Кабели и принадлежности User Manual

Page 110

background image

3. Installation

3−32

Festo P.BE−SPC200−EN en 0901d

Connection example

The following diagram shows the connection of a common
24 V supply for pin 1 (24 L) and pin 2 (24 V). Please note that:

ć

the voltage tolerance of 24 V DC −5/+25 % must be obĆ
served for the load voltage and electronics supply

ć

with regard to the load voltage supply, the voltage tolerĆ
ances of the components connected to the axis interface
string must also be observed.

PE

24L

AC
230V

DC
24V

24V

0 V

1

2

1

Separate supply cables

2

Load voltage (can be switched off separately)

Fig. 3/9:

Example ć connection of a common 24 V supply

Please note
Switching off the load voltage leads to faults (e.g. underĆ
voltage, AIF string faults) which must be quitted when the
load voltage is switched on again.