beautypg.com

Festo Кабели и принадлежности User Manual

Page 371

background image

8. Diagnosis and error treatment

8−15

Festo P.BE−SPC200−EN en 0901d

Fault class 2:

Reserved

Fault
stage

Fault
message

Operating status / fault explanation

Eliminating faults

ć

zzzyyx02

Reserved

Fault class 3:

Initialization phase User data damaged

Fault
stage

Fault
message

Operating status / fault explanation

Eliminating faults

A

zzz01x03

User program damaged
zzz = program number

·

Carry out Data Reset and
enter or load data again
or

00002x03

Position list damaged

or

·

Servicing required
If h f

l

h

00003x03

Configuration data damaged

g

q

·

If the fault occurs more than
once, check and if necessary

00004x03

System data damaged

once, check and if necessary
replace basic unit

00005x03

Dynamic identification data damaged

00006x03

Static identification data damaged

00007x03

Faulty PROFIBUS configuration data

00008x03

Faulty Interbus configuration data

00009x03

Faulty CANbus configuration data

zzz = Additional information
yy = Fault number
x