6. Operating the SPC200 with the control panel

6−32

Festo P.BE−SPC200−EN en 0901d

Exit program editor

1. First make sure that the cursor is positioned on an NC

command, parameter or operand. Then press the Enter
button in order to conclude the entry of the current NC
record. The cursor is then positioned on identifier N and
the NC record is intermediately saved in the SPC200.

P03:N005 M30

2. Press button

} in order to position the cursor on the NC

command again.

P03:N005 M30

3. Now press the Esc button. The NC editor will then be

exited.

When the NC editor is exited, the program is transferred from
the intermediate buffer (RAM memory) into the program
memory (flash memory). Failure of the operating voltage beĆ
fore the NC editor is exited will therefore lead to loss of the
modifications undertaken.