beautypg.com

Festo Кабели и принадлежности User Manual

Page 132

background image

3. Installation

3−54

Festo P.BE−SPC200−EN en 0901d

Special accessories are available here for CP input modules.
A terminating resistor is already incorporated in the I/O funcĆ
tion module.

5. Maximum permitted cable lengths

If the following cable lengths are exceeded, the external
load voltage supply must be installed in front of the relĆ
evant module. Instead of a CP valve terminal, a CP output
module type CP−A08−M12 can also be installed.

SPC−AIF−SUP−24V

SPC200

SPC−AIF−...

SPC−FIO−2E/2A

CPV−...−VI−FB−... ³

)

SPC200

SPC−AIF−...

CP−E16−M...

max. 8 m

1)

max. 8 m

max. 2 m

1)

max. 8 m

1)

max. 8 m

1

)

Without external load voltage supply

2)

Without external load voltage supply only type CPV10−VI−FB−6 or
type CPV14−VI−FB−6 is permitted

Fig. 3/21: Maximum permitted cable lengths on the axis

interface string (one axis)