5 controlling the program sequence, Controlling the program sequence – Festo Кабели и принадлежности User Manual
Page 258
6. Operating the SPC200 with the control panel
6−46
Festo P.BE−SPC200−EN en 0901d
6.5
Controlling the program sequence
Warning
Make sure that nobody can place his/her hand in the posiĆ
tioning range of the moveable mass and that no objects lie
in its path.
Prerequisite
In order to be able to control the sequence of programs with
the control panel, the following conditions must be fulfilled:
ć
the positioning system must be set up completely, wired
and supplied with power and compressed air
ć
the parameters in the menus AXIS PARAM, APLIC.PARAM
and CONFIG. SYSTEM must be set correctly
ć
the inputs ENABLE and STOP must supply a 1−signal
ć
there must be at least one program in the memory.
You can start and stop or reset the system with the following
commands in the menu SYSTEM CONTROL :
Menu SYSTEM CONTROL
SYSTEM CONTROL
START SYSTEM ?
Start system (only supported in Start/Stop mode)
With this command the sequence of created programs will then be
started or continued. Prerequisite:
Ĉ there must be a 1−signal at the STOP input
Ĉ there must be a 1−signal at the ENABLE input
When the system has been started the display will show the command
STOP SYSTEM, so that unintentional starting can be rejected immediĆ
ately.
SYSTEM CONTROL
STOP SYSTEM ?
Stop system
With this command the program sequence and the axes will be stopped.
The current position becomes the nominal position (controlled stop).