3. Installation
3−41
Festo P.BE−SPC200−EN en 0901d
Addressing
The assignment of the I/O address range depends on the
configuration of the SPC200. If a field bus module is inĆ
stalled, the address range 0.0 ... 0.9 will remain unassigned.
The assignment of the I/O addresses for configurations with
and without field bus module is shown in the following table:
Configuration without
field bus module
Configuration with
field bus module
Maximum address range
First I/O module
ć
I0.0 ... I0.9
1)
Q0.0 ... Q0.7
1)
I/O module on the first axis interface string
I1.0 ... I1.15
Q1.0 ... Q1.15
Second I/O module
First I/O module
I2.0 ... I2.9
Q2.0 ... Q2.7
I/O modules on the second axis interface string
I3.0 ... I3.15
Q3.0 ... Q3.15
Third I/O module
Second I/O module
I4.0 ... I4.9
Q4.0 ... Q4.7
Fourth I/O module
Third I/O module
I5.0 ... I5.9
Q5.0 ... Q5.7
ć
Field bus module
I10.0 ... I13.15
2)
Q10.0 ... Q13.15
2)
1)
Address range is not available if a field bus module is used
2)
Address range is not available without a field bus module
If a field bus module is not installed, certain I/Os on the first
identified I/O module are pre−assigned depending on the
operating mode.