3 command syntax, Command syntax – Festo Кабели и принадлежности User Manual
Page 290
7. Description of the commands
7−24
Festo P.BE−SPC200−EN en 0901d
7.3
Command syntax
The programs for the SPC200 are based on the syntax as per
DIN 66025.
An NC record consists of a record number as well as an NC
command with the relevant parameters.
Example:
N010 G01 G90 X100.00 FX10 Y100.00 FY80
1
2
3
4
5
4
5
1
Record number
2
NC command
3
Type of positioning (optional)
4
Positioning
5
Parameters
Fig. 7/4:
Example NC record
Record numbers
Each NC record is marked with a record number. Record
numbers begin with the letter N (for NC record number).
In the SPC200 the record numbers are numbered beginning
with N000 and a step size of 1 (therefore N000, N001,
N002, ...).
The record numbers can be numbered as desired in
ascending order in WinPISA.
Fixed jump targets are adapted accordingly when the
programs are translated and loaded into the SPC200. Take
this into account when specifying jump targets by register
(commands E05, #T, #TN, #TR).