Fault class 8:

NC Editor, Upload/download or operation execution fault

Fault
stage

Eliminating faults

Operating status / fault explanation

Fault
message

D

0000Fx08

Command or operating function not
permitted with active NC program

·

Stop the system and access
the command or operating
function again

D

00010x08

Controller is inactive, as enable signal for
first commissioning is missing or the
configuration is faulty
Only with stepping motor axis
Ĉ No Ready signal from the power controller

·

Generate rising edge at
ENABLE input or check conĆ
troller, axis and application
data

·

Correct fault on stepping
motor controller

ppp11x08

The NC program contains new NC commands
and extended NC syntax which is not
supported by control panel type
SPC200−MMI−1... (see also chapter 7.1.4).

·

Use WinPISA as from version
4.3, in order to edit such NC
programs.

ppp12x08

Movement test cannot be started as the
ENABLE input supplies a 1−signal.

Apply a 0−signal at the ENABLE
input

ppp13x08

Valve voltage cannot be modified as the
ENABLE input supplies a 0−signal.

Apply a 1−signal at the ENABLE
input

ppp14x08 Movement test is interrupted as ENABLE

input supplies a 0−signal.

None

ppp15008 Compatibility error between WinPISA, MMI

and the operating system version of the
SPC200. A program present in the SPC200
cannot be processed with the WinPISA
version being used.
ppp = program number

·

Use the latest WinPisa
version.

·

If necessary, delete all proĆ
grams and reload them into
the SPC200.

Please note: You can find the
current WinPISA version in
Festo’s download area
< festo.com>.

zzz = Additional information
yy = Fault number
x

= Axis identifier (0 = fault is not axis−related)

ppp = Program number