Festo Кабели и принадлежности User Manual
Page 387
8. Diagnosis and error treatment
8−31
Festo P.BE−SPC200−EN en 0901d
Fault class 8:
NC Editor, Upload/download or operation execution fault
Fault
stage
Eliminating faults
Operating status / fault explanation
Fault
message
D
0000Fx08
Command or operating function not
permitted with active NC program
·
Stop the system and access
the command or operating
function again
D
00010x08
Controller is inactive, as enable signal for
first commissioning is missing or the
configuration is faulty
Only with stepping motor axis
Ĉ No Ready signal from the power controller
·
Generate rising edge at
ENABLE input or check conĆ
troller, axis and application
data
·
Correct fault on stepping
motor controller
ppp11x08
The NC program contains new NC commands
and extended NC syntax which is not
supported by control panel type
SPC200−MMI−1... (see also chapter 7.1.4).
·
Use WinPISA as from version
4.3, in order to edit such NC
programs.
ppp12x08
Movement test cannot be started as the
ENABLE input supplies a 1−signal.
Apply a 0−signal at the ENABLE
input
ppp13x08
Valve voltage cannot be modified as the
ENABLE input supplies a 0−signal.
Apply a 1−signal at the ENABLE
input
ppp14x08 Movement test is interrupted as ENABLE
input supplies a 0−signal.
None
ppp15008 Compatibility error between WinPISA, MMI
and the operating system version of the
SPC200. A program present in the SPC200
cannot be processed with the WinPISA
version being used.
ppp = program number
·
Use the latest WinPisa
version.
·
If necessary, delete all proĆ
grams and reload them into
the SPC200.
Please note: You can find the
current WinPISA version in
Festo’s download area
< festo.com>.
zzz = Additional information
yy = Fault number
x
= Axis identifier (0 = fault is not axis−related)
ppp = Program number