7. Description of the commands
7−81
Festo P.BE−SPC200−EN en 0901d
M41
Set speed limit value
1)
ć pneumatic axis; ć permitted in operating mode: Start/Stop
Nn M41 X
value> n 1) Speed limit value in [m/s] or [10 3 °/s]; permitted: 0,01 Ţ Limit value Ţ defined maximum speed n = @n 1) Speed limit value in [m/s] or [10 3 °/s] saved in position register @n n = 0 ... 99 Effect If the speed of the drive exceeds the defined speed limit value when command M39 Example See M39 Remark This command has a saving effect. It remains effective until a new speed limit value 1) This syntax is only available as from operating system version 4.6. Programs which contain this
0.01 ... 9.99
is accessed, M39 will be deactivated, an appropriate fault will be shown and the
axis will be stopped (controlled stop).
Please note
When the stroke limit value (e.g. M40 X0) is switched off, the monitoring of the
speed limit value (M41) will also be switched off.
is defined.
syntax cannot be edited with control panel type SPC200−MMI−1... .