beautypg.com

Switch on the power supply – Festo Кабели и принадлежности User Manual

Page 159

background image

4. Commissioning

4−15

Festo P.BE−SPC200−EN en 0901d

Switch on the power supply

Warning
Leave the compressed air supply switched off. If comĆ
pressed air is applied, the connected actuators may carry
out sudden compensating movements as soon as the
power supply is switched on.

Make sure that nobody can place his/her hand in the posiĆ
tioning range of the moveable mass and that there are no
objects in its path.

Please note
If you are using control panel type SPC200−MMI−1F:

When the MMI−1F is switched on, it tries to communicate
with the SPC200. The SPC200 must therefore be ready for
communication.

Switch on the power supplies for the SPC200 and the
MMI−1F therefore either simultaneously or in the following
sequence:

1. first the power supply for the SPC200

2. then the power supply for the MMI−1F.

·

Switch on the operating voltage and the load voltage for
the SPC200 and, if necessary, the operating voltage for
the control panel type SPC200−MMI−1F.

When the power supply is applied, the SPC200 automatically
performs an internal test. If the control panel is inserted, it
will display the current fault number in the event of a fault
(see section 8.2). When the device is switched on the first
time, the following fault code will be displayed.

ERROR

no. 00004001