Festo Кабели и принадлежности User Manual
Page 180
4. Commissioning
4−36
Festo P.BE−SPC200−EN en 0901d
Step 5:
Move the axis by means of the control
panel (optional)
Necessary control signals:
1−signal at ENABLE, STOP and READY.
With the command JOG AXIS in the menu TEST/DIAG. you
can move the axis manually. Proceed as follows:
1. Select the submenu AXIS in the menu TEST/DIAG. and
press the Enter button.
TEST/DIAG. AXIS
X:
2. The cursor is positioned on the axis identifier. Select the
desired axis with the buttons
vV (here X) and press
the Enter button. The command JOG AXIS in the submenu
AXIS will then be displayed.
TEST/DIAG. AXIS
JOG AXIS >
3. Press the Enter button in order to select the command.
The previously selected axis and the current positioning
mode will then be displayed.
JOG AXIS
X: CONT
4. Select the desired positioning mode with
vV.
Meaning:
Positioning mode
Meaning
CONT
Position continuously
STEP
Position in steps twice the set
positioning tolerance