8. Diagnosis and error treatment
8−28
Festo P.BE−SPC200−EN en 0901d
Fault class 7:
Fault in the pre−parametrizing
Fault
stage
Fault
message
Operating status / fault explanation
Eliminating faults
C
00001x07
Software end position lies outside the
possible positioning range
·
Correct parameter
(permitted value ranges see
chapter 6 2)
00002x07
Mass load lies outside the permitted range
00003x07
Gain factor not permitted
00004x07
Damping factor not permitted
00005x07
Filter factor not permitted
00006x07
Measuring system length not valid or
measured value outside the set cylinder
length
00007x07
Parameter limit violated
00008x07
Measuring system type not permitted
00009x07
Reserved
ć
0000Ax07 Max. permitted step frequency (positioning
frequency) exceeded (>40000 Hz)
·
Check resolution or reduce
positioning speed
0000Bx07 Reserved
ć
0000Cx07
Adaptation data incorrect
·
Carry out Data Reset
zzz = Additional information
yy = Fault number
x
= Axis identifier (0 = fault is not axis−related)