beautypg.com

Festo Кабели и принадлежности User Manual

Page 397

background image

A. Notes on installing the pneumatic components

A−5

Festo P.BE−SPC200−EN en 0901d

Installation instructions for drives DGP(L)−... and
DGPI(L)−...

ć

Any mounting position is permitted (horizontal, vertical or
diagonal)

·

Note that in conjunction with the SPC200, the complete
stroke of the drive must not be used.

Permitted work stroke = stroke length minus stroke
reduction

1

Permitted work
stroke = (stroke
length minus
stroke reduction)

2

Stroke reduction

1

2

Fig. A/3:

Permitted working stroke

On each side of the drive positioning must

not take place in

the range of the stroke reduction (see also section 3.4).

ć

The best possible positioning behaviour can be
achieved if you use only 80 % of the stroke length of
the drive, symmetrically to the two end positions.

ć

If demands placed on the positioning behaviour are
only slight, observe at least the following stroke reĆ
ductions in both end positions:

Pistonj [mm]

25

32

40

50

63

Stroke reductionper end position [mm]

25

25

35

35

35