beautypg.com

Festo Кабели и принадлежности User Manual

Page 364

background image

8. Diagnosis and error treatment

8−8

Festo P.BE−SPC200−EN en 0901d

Short circuit
sensor supply

If there is a short circuit, the input module will switch off the
power supply to the sensors self−locking and communicate
the fault to the SPC200. The status LEDs will be switched off
and the inputs of the module supply a 0−signal. After eliminĆ
ating the short circuit, delete this fault by quitting.

Status display

Next to the sensor connections there are green LEDs. These
show the status of the signal at the relevant input. The LEDs
indicate the following:

Status LED

Sequence

Status

ON

OFF

Logical 1 (signal present)

ON

OFF

Logical 0 (no signal)

ON

OFF

Only in the switch−on phase, if:
Ĉ there is a 1−signal and
Ĉ there is an assignment fault on

the axis interface string.