6. Operating the SPC200 with the control panel
6−47
Festo P.BE−SPC200−EN en 0901d
Menu SYSTEM CONTROL
SYSTEM CONTROL
RESET SYSTEM ?
Reset system
The SPC200 is reset to the status it was in when it was switched on.
A program reset and a hardware recognition are carried out here and
the axis interface string is re−initialized. This procedure can take a
certain amount of time, depending on the system configuration used.
SYSTEM CONTROL
RESET PROGRAMS ?
Reset program
Prerequisites:
Ĉ there must be a 1−signal at the ENABLE input
This will have the following effects:
Ĉ the NC record pointer is reset to 0
Ĉ the pre−settings G90 and G02 (speed and acceleration values and
workpiece mass in initial state), as well as the positioning quality
class set in the application data become valid
Ĉ the nominal value input is switched off (M12)
Ĉ all settings undertaken with M10, M11, M13 or M14 are reset to the
defined standard values (parameter set for the axis, Nominal value
specification" tab)
Ĉ pre−switch off values defined with G25 are reset again
Ĉ direct control of the valve voltage (M39) is deactivated
Ĉ all settings undertaken with M40 and M41 are reset to the standard
values
Ĉ all freely programmable outputs and the SYNC outputs are reset
Ĉ the set starting programs are made available
Ĉ any faults are acknowledged.
SYSTEM CONTROL
RESET ERROR ?
Reset fault
Prerequisites:
Ĉ there must be a 1−signal at the ENABLE input
With this command the fault code is reset to 0.
SYSTEM CONTROL
RESET DATA ?
Reset all data to the status as at delivery
With this command all data are reset to the status as at delivery.
All user data will be lost.