3. Installation

3−57

Festo P.BE−SPC200−EN en 0901d

The axis interface provides the connection between the comĆ
ponents on the axis and the SPC200. It reads the values supĆ
plied by the measuring system and passes them onto the
SPC200. It also passes the received positioning values in
analogue form to the proportional directional control valve.

The diagram below shows the connecting elements on the
axis interface.

ERROR

OUT

VALVE

IN

POWER

1

2

3

4

5

6

7

1

Earth/ground connection

2

Connection, axis interface string, incoming (IN)

3

POWER LED (green)

4

Connection, axis interface string, continuing (OUT),
for further field devices or teminating resistor
typeĂKABS−M9−R100

5

ERROR LED (red)

6

Connection for valve
type MPYE−5−...−010−B

7

Measuring system
connection (here
type SPC−AIF−POT)

Fig. 3/23: Connecting elements of the axis interface