beautypg.com

Festo Кабели и принадлежности User Manual

Page 469

background image

C. Technical appendix

C−23

Festo P.BE−SPC200−EN en 0901d

Type

SPC200−PWR−AIF

Temperature range
Ĉ Operation
Ĉ Storage/transport

− 5 ... + 50 °C
− 20 ... + 70 °C

Weight

82 g

Relative humidity

95 %, non−condensing

Operating voltage at pin 1 (load voltage)
Ĉ Rated value
Ĉ Tolerance

1)

Ĉ Residual ripple
Ĉ Current consumption (SPC200−CPU−4 and

SPC200−CPU−6)

24 V DC
−5 ... +25 % (22.8...30.0 V DC)
2 %
500 mA + 1.2 A per pneumatic axis

Operating voltage at pin 2 (internal electronics)
Ĉ Rated value
Ĉ Tolerance
Ĉ Residual ripple
Ĉ Power failure bridging time
Current consumption with:
Ĉ SPC200−CPU−4

Ĉ SPC200−CPU−6

24 V DC
−5 ... +25 % (22.8...30.0 V DC)
2%
10 ms

400 mA + current requirement of the components
connected to the sensor supply

2)

+ sum of curĆ

rent consumption on the AIF string

3)

600 mA + current requirement of the components
connected to the sensor supply

2)

+ sum of curĆ

rent consumption on the AIF string

3)

CE symbol (declaration of conformity)
è

www.festo.com

In accordance with EU EMC Directive

Vibration and shock
Ĉ Vibration

Ĉ Shock

Tested as per DIN/IEC 68 part 2−6:
0.15 mm path at 10...58 Hz;
2 g acceleration at 58...150 Hz
Tested as per DIN/IEC 68 part 2−27:
± 30 g at 11 ms duration; 5 shocks per direction

1)

Observe the tolerance of the modules connected to the axis interface string.

2)

Maximum 0.5 A be made available for each I/O module type SPC200−DIO.

3)

See technical specifications of the connected modules.

The component is intended for industrial use.