Festo Кабели и принадлежности User Manual
Page 351
7. Description of the commands
7−85
Festo P.BE−SPC200−EN en 0901d
#S
Set single−bit operand
ć permitted in operating modes: Start/Stop
Nn #S
Fn
Flag with number Fn
n = 0 ... 63
Qn.n
Outputs: all freely programmable outputs
n.n =
0.0 ... 13.15
Effect
The specified single−bit operand is set.
Permitted operands are all single−bit operands, but not inputs.
See also chapter 7.2.1.
Example
N010 #SQ0.0
;Set output Q0.0
Output Q0.0 supplies a 1−signal when this record is processed.
Remark
Certain outputs are reserved for pre−assigned functions.
Flags are remanent.
#R
Reset single−bit operand
ć permitted in operating modes: Start/Stop
Nn #R
Fn
Flag with number Fn
n = 0 ... 63
Qn.n
Outputs: all freely programmable outputs
n.n = 0.0 ... 13.15
Effect
The specified single−bit operand is reset.
Permitted operands are all single−bit operands, but not inputs.
See also chapter 7.2.1.
Example
N010 #RQ0.0
;Reset output Q0.0
Output Q0.0 supplies a 0−signal when this record is processed.
Remark
Certain outputs are reserved for pre−assigned functions.
Flags are remanent.