beautypg.com

Festo Кабели и принадлежности User Manual

Page 351

background image

7. Description of the commands

7−85

Festo P.BE−SPC200−EN en 0901d

#S

Set single−bit operand

ć permitted in operating modes: Start/Stop

Nn #S

Fn

Flag with number Fn

n = 0 ... 63

Qn.n

Outputs: all freely programmable outputs

n.n =
0.0 ... 13.15

Effect

The specified single−bit operand is set.
Permitted operands are all single−bit operands, but not inputs.
See also chapter 7.2.1.

Example

N010 #SQ0.0

;Set output Q0.0

Output Q0.0 supplies a 1−signal when this record is processed.

Remark

Certain outputs are reserved for pre−assigned functions.
Flags are remanent.

#R

Reset single−bit operand

ć permitted in operating modes: Start/Stop

Nn #R

Fn

Flag with number Fn

n = 0 ... 63

Qn.n

Outputs: all freely programmable outputs

n.n = 0.0 ... 13.15

Effect

The specified single−bit operand is reset.
Permitted operands are all single−bit operands, but not inputs.
See also chapter 7.2.1.

Example

N010 #RQ0.0

;Reset output Q0.0

Output Q0.0 supplies a 0−signal when this record is processed.

Remark

Certain outputs are reserved for pre−assigned functions.
Flags are remanent.