4. Commissioning
4−31
Festo P.BE−SPC200−EN en 0901d
The movement test can be interrupted by a 0−signal at the
ENABLE input. The valve voltages will then be set to an elecĆ
trical medium value (offset). An appropriate fault message
will then appear on the control panel.
10. Modify the control voltage until the drive starts to move
slowly.
11. Make sure that the drive moves in the correct direction
(see under 9.). Adjust the tubing if the drive moves in the
wrong direction (see also appendix A).
12. In order to conclude the movement test and to reset the
control voltage to 5 V again, press the ESC button. The
control panel then shows the following again.
TEST/DIAG. AXIS
MOVEMENT TEST >
13. In order to conclude this procedure, apply a 0−signal once
again to the ENABLE input.
14. If you wish to carry out the movement test with the same
axis again, proceed now as described as from point 7.
15. If you wish to carry out the movement test with a different
axis, press the ESC button. Then proceed as described as
from point 5.
In order to return to the basic setting, press the ESC
button several times.