7. Description of the commands

7−14

Festo P.BE−SPC200−EN en 0901d

7.2

Addressing, registers and axis status flags

The SPC200 knows different operators, variables and flags
which can be used in the program for controlling a positionĆ
ing sequence.

A distinction is made between 1−bit, integer and real variĆ
ables; between remanent and non−remanent variables.
All the inputs and outputs of the SPC200 are treated like 1−bit
variables.

7.2.1

Addressing

The following operands are supported:

Operand

Description

Address range

Value range

I

Input

I0.0 ... I13.15

1)

0/1

Q

Output

Q0.0 ... Q13.15

1)

0/1

F

Flag

2)

F0 ... F63

0/1

F

Axis status flag

F64 ... F127

0/1

R

Register

2)

R0 ... R99

−32768...+32767

@

100 position register per axis

2)

@0...@99

3)

−9999.98...+9999.99

4)

1)

Available address range see following table

2)

These operands are saved and protected against power failure (remanent)

3)

In the case of programming with WinPISA, symbolic names for positions can also be used
(e.g. X@ABLAGE_POS). These are replaced by the position register numbers during Download.

4)

The control panel the value −9999.99 (smallest permitted position value) with unused position
registers.