7. Description of the commands
7−80
Festo P.BE−SPC200−EN en 0901d
M40
Set stroke limit value
1)
ć pneumatic axis; ć permitted in operating mode: Start/Stop
Nn M40 X
value> n 1) Stroke limit value in [mm] or [°]; Z Stroke limit value isswitched off permitted: 0 Ţ Limit value Ţ stroke length or angle n = @n 1) Stroke limit value in [mm] or [°] saved in the position n = 0 ... 99 Effect If the drive exceeds the defined stroke limit value when command M39 is accessed Example See M39 Remark This command has a saving effect. It remains effective until a new stroke limit value 1) This syntax is only available as from operating system version 4.6. Programs which contain this
0
0 ... 9999.99
register @n
(in positive or negative direction), M39 will be deactivated, an appropriate fault will
be shown and the axis will be stopped (controlled stop).
If 0 is specified as the stroke limit value, the drive can move freely between the
software end positions.
In the case of drives with an incremental measuring system (e.g. B. DNCI−...)
without reference travel carried out, the axis can move freely without limits.
Please note
When the stroke limit value (e.g. M40 X0) is switched off, the monitoring of the
speed limit value (M41) will also be switched off.
is defined.
syntax cannot be edited with control panel type SPC200−MMI−1... .