7. Description of the commands
7−19
Festo P.BE−SPC200−EN en 0901d
NC
command
Function
The register
contents may be
Unit
1)
As from operating
system version
G25
Switch to next record
Position
mm
4.63
G28
mm
3.8
G28
G29
M38
Register operation
After defining
m/s
4.63
M38
g
p
g
m/s
2
4.63
M40
Positioning parameter
Limit value
mm
4.63
M41
Positioning parameter
Limit value
m/s
4.63
M37
Positioning parameter
Tool load or
mass moment of
inertia
Kg
Kgm
2
* 10
−4
4.82
M10
Positioning command
Scaling factor
mm/V
4.82
M11
Positioning parameter
Offset value
mm
4.82
1)
With rotary drives correspondingly °, °/s, °/s
2
7.2.4
Register Rn
In the SPC200 100 R−registers can be used within the proĆ
grams. They have the identifier Rn {n=0...99}, are integer
variables and can accept values from −32768 ... +32767.
R−registers are saved remanently, i.e. they are saved in the
event of Power−off and loaded back into the work memory
with Power−on.
The registers can be parametrized with the MMI and
WinPISA, whereby the limiting instructions on page XVI must
be observed.