7. Description of the commands

7−19

Festo P.BE−SPC200−EN en 0901d

NC
command

Function

The register
contents may be

Unit

1)

As from operating
system version

G25

Switch to next record

Position

mm

4.63

G28

mm

3.8

G28
G29
M38

Register operation

After defining

m/s

4.63

M38

g

p

g

m/s

2

4.63

M40

Positioning parameter

Limit value

mm

4.63

M41

Positioning parameter

Limit value

m/s

4.63

M37

Positioning parameter

Tool load or
mass moment of
inertia

Kg
Kgm

2

* 10

−4

4.82

M10

Positioning command

Scaling factor

mm/V

4.82

M11

Positioning parameter

Offset value

mm

4.82

1)

With rotary drives correspondingly °, °/s, °/s

2

7.2.4

Register Rn

In the SPC200 100 R−registers can be used within the proĆ
grams. They have the identifier Rn {n=0...99}, are integer
variables and can accept values from −32768 ... +32767.
R−registers are saved remanently, i.e. they are saved in the
event of Power−off and loaded back into the work memory
with Power−on.
The registers can be parametrized with the MMI and
WinPISA, whereby the limiting instructions on page XVI must
be observed.