Festo Кабели и принадлежности User Manual
Page 361
8. Diagnosis and error treatment
8−5
Festo P.BE−SPC200−EN en 0901d
Reaction
Sequence
Operating status
Eliminating faults
ERROR LED
ON
OFF
Ĉ Switch−on phase (3...4 seconds)
or
Ĉ Hardware fault, SPC200 is not
ready for communication
·
None
·
Servicing required
ON
OFF
No internal fault registered
None
ON
OFF
Ĉ Lights up briefly once when the
device is switched on
None
Flashing sequence according to the
fault class with a 1−second break
Ĉ Flashes once (fault class 1)
Initialization fault
Ĉ Flashes twice (fault class 2)
reserved
Ĉ Flashes three times (fault class 3)
User data damaged
Ĉ Flashes four times (fault class 4)
Hardware fault during running
time
Ĉ Flashes five times (fault class 5)
Sequence control fault
Ĉ Flashes six times (fault class 6)
Fault in positioning task
Ĉ Flashes seven times (fault 7)
Pre−parametrizing fault
Ĉ Does not flash (fault class 8)
Ĉ Flashes nine times (fault class 9)
Trace fault
Ĉ Flashes continuously without
break Firmware deleted by user
·
Install components and
modules correctly or replace
defective module
1) 2)
·
(Reserved)
·
Carry out Data Reset and
enter or load data again
1) 2)
·
Read out fault message and
eliminate fault
1)
·
Read out fault message and
eliminate fault
1)
·
Read out fault message and
eliminate fault
1)
·
Read out fault message and
eliminate fault
1)
·
None
·
Carry out Data Reset and
enter or load data again
1) 2)
·
Load firmware
1)
Read out fault message and eliminate fault (see section 8.2)
2)
Or servicing required