8. Diagnosis and error treatment

8−5

Festo P.BE−SPC200−EN en 0901d

Reaction

Sequence

Operating status

Eliminating faults

ERROR LED

ON

OFF

Ĉ Switch−on phase (3...4 seconds)

or

Ĉ Hardware fault, SPC200 is not

ready for communication

·

None

·

Servicing required

ON

OFF

No internal fault registered

None

ON

OFF

Ĉ Lights up briefly once when the

device is switched on

None

Flashing sequence according to the
fault class with a 1−second break
Ĉ Flashes once (fault class 1)

Initialization fault

Ĉ Flashes twice (fault class 2)

reserved

Ĉ Flashes three times (fault class 3)

User data damaged

Ĉ Flashes four times (fault class 4)

Hardware fault during running
time

Ĉ Flashes five times (fault class 5)

Sequence control fault

Ĉ Flashes six times (fault class 6)

Fault in positioning task

Ĉ Flashes seven times (fault 7)

Pre−parametrizing fault

Ĉ Does not flash (fault class 8)
Ĉ Flashes nine times (fault class 9)

Trace fault

Ĉ Flashes continuously without

break Firmware deleted by user

·

Install components and
modules correctly or replace
defective module

1) 2)

·

(Reserved)

·

Carry out Data Reset and
enter or load data again

1) 2)

·

Read out fault message and
eliminate fault

1)

·

Read out fault message and
eliminate fault

1)

·

Read out fault message and
eliminate fault

1)

·

Read out fault message and
eliminate fault

1)

·

None

·

Carry out Data Reset and
enter or load data again

1) 2)

·

Load firmware

1)

Read out fault message and eliminate fault (see section 8.2)

2)

Or servicing required