6. Operating the SPC200 with the control panel

6−14

Festo P.BE−SPC200−EN en 0901d

AXIS PARAM.
X:

Enter

1

2

3

4

5

Enter

AXIS PARAM.
CYL. TYPE >

CYL. TYPE
X: 1

1

Menu AXIS PARAM. is open

2

Axis identifier can be selected, selection with

vV

3

Parameter Cylinder type can be selected

4

Current setting of the X−axis (here cylinder type 1)

5

Axis identifier display (here for X−axis)

Fig. 6/6:

Functions of the display lines

The top line then shows the selection made (here AXIS
PARAM.) as an orientation aid. When entering axis−specific
parameters you can then select the desired axis. In this case
the cursor is positioned on the axis identifier.

For this purpose, the relevant axis must be connected to the
SPC200 and the current hardware configuration must be
saved.