beautypg.com

Festo Кабели и принадлежности User Manual

Page 233

background image

6. Operating the SPC200 with the control panel

6−21

Festo P.BE−SPC200−EN en 0901d

Menu APPLIC. PARAM (application data)

Pneumatic axis

FITTING OFFS.

X:+0000.00

Mounting offset
−10000 ... +10000 [mm] or [°]
Offset between measurement system zero point and cylinder zero point.
The mounting offset is positive if the cylinder zero point lies within the
measuring system range. Set the mounting offset so that approximately
0 is shown as the actual position on the cylinder zero point.
The mounting offset is negative if the cylinder zero point lies outside the
measuring system range.

POS. BASEPOINT

X:+0000.00

Project zero point
−10000 ... +10000 [mm] or [°]
Specifies the point of the axis to which the positions contained in the
position registers and programs refer. The project zero point refers to
the cylinder zero point.

LOWER END POS.

X:+0000.00

Lower software end position
0.0 ... 10000 [mm] or [°]
End position on the side of the measuring system zero point monitored
by the operating system (software) of the SPC200 and which must not
be overrun. If both software end positions are set to 0, their function
will have no effect. The lower software end position refers to the cylinĆ
der zero point and represents the lower limit of the positioning range.

UPPER END POS.

X:+0000.00

Upper software end position
0.0 ... 10000 [mm] or [°]
End position on the side opposite the measuring system zero point
monitored by the operating system (software) of the SPC200 and which
must not be overrun. If both software end positions are set to 0, their
function will have no effect.
The upper software end position refers to the cylinder zero point and
represents the upper limit of the positioning range.

POS. TOLERANCE

X:+0000.00

Positioning tolerance
0.1 ... 10.00 [mm] or [°]
This parameter specifies the repetition accuracy with which a positionĆ
ing procedure is to be carried out.