6. Operating the SPC200 with the control panel
6−30
Festo P.BE−SPC200−EN en 0901d
5. The cursor is positioned on the axis identifier. If several
axes are configured, select the desired axis with the butĆ
tons
vVand then press button }.
P03:N000 G00 *
X+0000.00
6. If the cursor is positioned next to the axis identifier, you
can switch between the following with the buttons
vV:
ć
position value (X+0000.00 or X−0000.00)
ć
register value (X@00)
ć
axis not relevant (X*)
Meaning: The positioning command has no effect for
the relevant axis.
7. If you have made your choice, you can set the position
value or register value with the cursor buttons. Proceed
as usual figure−by−figure:
·
position the cursor on the figure with
{and }
·
increase/decrease the figure value with
vV.
P03:N000 G00 *
X+0123.45
8. If you also wish to specify a position in the current NC
record for the second axis, then position the cursor again
on the axis identifier with the button
{. Then switch to
the desired axis and set the position or register value for
this axis with the cursor buttons, e.g.:
P03:N000 G00 *
Y+0100.00
The NC record entered in this example would appear as
follows in WinPISA: