beautypg.com

Festo Кабели и принадлежности User Manual

Page 242

background image

6. Operating the SPC200 with the control panel

6−30

Festo P.BE−SPC200−EN en 0901d

5. The cursor is positioned on the axis identifier. If several

axes are configured, select the desired axis with the butĆ
tons

vVand then press button }.

P03:N000 G00 *

X+0000.00

6. If the cursor is positioned next to the axis identifier, you

can switch between the following with the buttons

vV:

ć

position value (X+0000.00 or X−0000.00)

ć

register value (X@00)

ć

axis not relevant (X*)
Meaning: The positioning command has no effect for
the relevant axis.

7. If you have made your choice, you can set the position

value or register value with the cursor buttons. Proceed
as usual figure−by−figure:

·

position the cursor on the figure with

{and }

·

increase/decrease the figure value with

vV.

P03:N000 G00 *

X+0123.45

8. If you also wish to specify a position in the current NC

record for the second axis, then position the cursor again
on the axis identifier with the button

{. Then switch to

the desired axis and set the position or register value for
this axis with the cursor buttons, e.g.:

P03:N000 G00 *

Y+0100.00

The NC record entered in this example would appear as
follows in WinPISA:

N0000 G00 X+123.45 Y100.00