6. Operating the SPC200 with the control panel

6−53

Festo P.BE−SPC200−EN en 0901d

Menu TEST/DIAG. (test and diagnosis)

Sub−menu SYSTEM

SINGLE STEP

P00

Program test in single steps
P00 ... P99
(only supported in Start/Stop mode)
With this function you can test an existing program in single−step mode.
Proceed as follows:
1. Set the program number.
2. Press the Enter button to confirm the selection.
3. Press the Enter button to start the NC record.
4. Repeat point 3 in order to start the next NC record.

INPUT TEST

I0.00:0

Input test

1)

I = input
I0.00 ... I5.15.
With this command you can test the inputs of the system to make sure
that they function. The input signal entered fades out the real signal
and is taken into account for sequence control (e.g. Start/Stop) as well
as for the program sequence. Thereafter the actual input signal is valid
once again.

FB INPUT TEST

I10.00:0

Test field bus inputs

1)

I = input
I10.00 ... I13.15.

OUTPUT TEST

Q0.00:0

Output test

1)

Q = output
Q0.00 ... Q5.15
The READY output and the ACK outputs used by the system are
permanently updated by the operating system and cannot therefore be
influenced.

FB OUTPUT TEST

Q10.00:0

Test field bus outputs

1)

Q = output
Q10.00 ... Q13.15

FLAG TEST

F00:0

Test flags

1)

F = flag
F00 ... F63

REGISTER TEST

R00:0

Test register

1)

R = register
R00 ... R99

1)

With this command the status of the relevant operand can be modified.