7. Description of the commands
7−73
Festo P.BE−SPC200−EN en 0901d
During an axis stop with the M12 command the actual posiĆ
tion will be accepted as the new nominal position.
Warning
If an interfering variable causes a deviation between the
actual and nominal positions, the constant repetition of
the axis stop command (M12) can cause the drive to drift.
Each time the M12 command is accessed, the new actual
position will be accepted again as the new nominal posiĆ
tion.
Avoid the drifting by programming a locking which will
prevent the constant repetition of the axis stop command
(M12).
M13
Set nominal value mode
ć permitted in operating modes: Start/Stop
Nn M13 X
n
Mode; explanation see table below.
n = 0...4
Effect
Switches to the specified mode (see following table).
Example
Example see under M10