6. Operating the SPC200 with the control panel

6−49

Festo P.BE−SPC200−EN en 0901d

Menu DISPLAY

MEMORY FLAG

F00:0

Status display for flags
F = flag
F00 ... F63

REGISTER

R00:+0000

Status display for registers
R = register
R00 ... R99

ERROR

no. 00000000

Fault number
(see chapter 8.2)

STEP MOTOR

INPUT

Y: LIM+ = 1

Status display for sensors of the electric
axis
If the cursor is positioned on LIM+ , you
can switch between:
Ĉ LIM+ (positive limit switch)
Ĉ LIM− (negative limit switch)
Ĉ REF (reference switch)
Ĉ SRDY (ready signal of the stepping

motor controller)

The status of the relevant input is shown
by 0" or 1". If a stepping motor indexer
module is not installed, the message NO
STEP MOTOR" will appear.

When checking the sensors note their different designs:

ć

LIM+, LIM−:
Limit switches: N.C. (normally closed)

ć

REF:
Reference switches: N.O. (normally open)