Configuring ipv6 pim common timers, Configuring ipv6 pim common timers globally, Configuring ipv6 pim common timers on an interface – H3C Technologies H3C SecPath F1000-E User Manual
Page 893: Configuring ipv6 pim, Common timers
868
Configuring IPv6 PIM common timers
IPv6 PIM routers discover IPv6 PIM neighbors and maintain IPv6 PIM neighboring relationships with
other routers by periodically sending hello messages.
After receiving a hello message, an IPv6 PIM router waits a random period, which is smaller than the
maximum delay between hello messages, before sending a hello message. This avoids collisions that
occur when multiple IPv6 PIM routers send hello messages simultaneously.
An IPv6 PIM router periodically sends join/prune messages to its upstream for state update. A join/prune
message contains the join/prune timeout time. The upstream router sets a join/prune timeout timer for
each pruned downstream interface.
Any router that has lost assert election will prune its downstream interface and maintain the assert state
for a period of time. When the assert state times out, the assert loser will resume IPv6 multicast
forwarding.
When a router fails to receive subsequent IPv6 multicast data from the IPv6 multicast source S, the router
does not immediately delete the corresponding (S, G) entry. Instead, it maintains the (S, G) entry for a
period of time (the IPv6 multicast source lifetime) before deleting the (S, G) entry.
Configuring IPv6 PIM common timers globally
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter IPv6 PIM view.
pim ipv6
N/A
3.
Configure the hello interval.
timer hello interval
Optional.
30 seconds by default.
4.
Configure the join/prune
interval.
timer join-prune interval
Optional.
60 seconds by default.
5.
Configure the join/prune
timeout time.
holdtime join-prune interval
Optional.
210 seconds by default.
6.
Configure assert timeout time. holdtime assert interval
Optional.
180 seconds by default.
7.
Configure the IPv6 multicast
source lifetime.
source-lifetime interval
Optional.
210 seconds by default.
Configuring IPv6 PIM common timers on an interface
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter interface view.
interface interface-type
interface-number
N/A
3.
Configure the hello interval.
pim ipv6 timer hello interval
Optional.
30 seconds by default.
- H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS H3C SecBlade LB Cards H3C SecPath L1000-A Load Balancer