# On Router C, configure GigabitEthernet 0/1 and GigabitEthernet 0/5 as the boundary of

admin-scoped zone 2.

system-view

[RouterC] interface GigabitEthernet 0/1

[RouterC-GigabitEthernet0/1] multicast boundary 239.0.0.0 8

[RouterC-GigabitEthernet0/1] quit

[RouterC] interface GigabitEthernet 0/5

[RouterC-GigabitEthernet0/5] multicast boundary 239.0.0.0 8

[RouterC-GigabitEthernet0/5] quit

# On SecPath B, configure GigabitEthernet0/1 as the boundary of admin-scoped zone 2.

system-view

[SecPathB] interface GigabitEthernet 0/1

[SecPathB-GigabitEthernet0/1] multicast boundary 239.0.0.0 8

[SecPathB-GigabitEthernet0/1] quit

4.

Configure C-BSRs and C-RPs:
# On SecPath A, configure the service scope of RP advertisements and configure GigabitEthernet
0/4 as a C-BSR and C-RP of admin-scoped zone 1.

[SecPathA] acl number 2001

[SecPathA-acl-basic-2001] rule permit source 239.0.0.0 0.255.255.255

[SecPathA-acl-basic-2001] quit

[SecPathA] pim

[SecPathA-pim] c-bsr group 239.0.0.0 8

[SecPathA-pim] c-bsr GigabitEthernet 0/4

[SecPathA-pim] c-rp GigabitEthernet 0/4 group-policy 2001

[SecPathA-pim] quit

# On SecPath B, configure the service scope of RP advertisements and configure GigabitEthernet
0/3 as a C-BSR and C-RP of admin-scoped zone 2.

[SecPathB] acl number 2001

[SecPathB-acl-basic-2001] rule permit source 239.0.0.0 0.255.255.255

[SecPathB-acl-basic-2001] quit

[SecPathB] pim

[SecPathB-pim] c-bsr group 239.0.0.0 8

[SecPathB-pim] c-bsr GigabitEthernet 0/3

[SecPathB-pim] c-rp GigabitEthernet 0/3 group-policy 2001

[SecPathB-pim] quit

# On SecPath C, configure GigabitEthernet 0/1 as a C-BSR and C-RP in the global-scoped zone.

system-view

[SecPathC] pim

[SecPathC-pim] c-bsr global

[SecPathC-pim] c-bsr GigabitEthernet 0/1

[SecPathC-pim] c-rp GigabitEthernet 0/1

[SecPathC-pim] quit

5.

Verify the configuration:
To display BSR election information and C-RP information on a firewall, use the display pim

bsr-info command. For example:
# Display BSR information and the locally configured C-RP information on SecPath A.

[SecPathA] display pim bsr-info