H3C Technologies H3C SecPath F1000-E User Manual
Page 717
692
perform corresponding operations.
lists and describes the configurable parameters in an RA
message.
Table 85 Parameters in an RA message and their descriptions
Parameters Description
Cur Hop Limit
When sending an IPv6 packet, a host uses the value to fill the Hop Limit field in IPv6
headers. The value is also filled into the Hop Limit field in the response packet of a
device.
Prefix Information
options
After receiving the prefix information, the hosts on the same link can perform
stateless autoconfiguration.
MTU
Make sure that all nodes on a link use the same MTU value.
M flag
Determines whether hosts use the stateful autoconfiguration to acquire IPv6
addresses.
If the M flag is set to 1, hosts use the stateful autoconfiguration (for example, through
a DHCP server) to acquire IPv6 addresses. Otherwise, hosts use the stateless
autoconfiguration to acquire IPv6 addresses and generate IPv6 addresses
according to their own link-layer addresses and the obtained prefix information.
O flag
Determines whether hosts use stateful autoconfiguration to acquire other
configuration information.
If the O flag is set to 1, hosts use stateful autoconfiguration (for example, through a
DHCP server) to acquire other configuration information. Otherwise, hosts use
stateless autoconfiguration to acquire other configuration information.
Router Lifetime
This field tells the receiving hosts how long the advertising device can live
Retrans Timer
If the device fails to receive a response message within the specified time after
sending an NS message, it will retransmit the NS message.
Reachable Time
If the neighbor reachability detection shows that a neighbor is reachable, the
device considers the neighbor reachable within the specified reachable time. If the
device needs to send a packet to the neighbor after the specified reachable time
expires, the device will reconfirm whether the neighbor is reachable.
To allow sending of RA messages:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter interface
view.
interface interface-type
interface-number
N/A
3.
Disable RA
message
suppression.
undo ipv6 nd ra halt
By default, RA messages are suppressed.
4.
Configure the
maximum and
minimum intervals
for sending RA
messages.
ipv6 nd ra interval
max-interval-value
min-interval-value
Optional.
By default, the maximum interval for sending RA
messages is 600 seconds, and the minimum interval is
200 seconds.
The device sends RA messages at random intervals
between the maximum interval and the minimum interval.
The minimum interval should be less than or equal to 0.75
times the maximum interval.
- H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS H3C SecBlade LB Cards H3C SecPath L1000-A Load Balancer