Assigning an access port to a vlan – H3C Technologies H3C SecPath F1000-E User Manual
Page 65
40
Port type
Actions (in the inbound direction)
Actions (in the outbound
direction)
Untagged frame
Tagged frame
Access
Tags the frame with the
PVID tag.
•
Receives the frame if its
VLAN ID is the same as the
PVID.
•
Drops the frame if its VLAN
ID is different from the
PVID.
Removes the VLAN tag and
send the frame.
Trunk
Checks whether the PVID
is permitted on the port:
•
If yes, tags the frame
with the PVID tag.
•
If not, drops the
frame.
•
Receives the frame if its
VLAN is carried on the
port.
•
Drops the frame if its VLAN
is not carried on the port.
•
Removes the tag and send
the frame if the frame carries
the PVID tag and the port
belongs to the PVID.
•
Sends the frame without
removing the tag if its VLAN
is carried on the port but is
different from the default
one.
Hybrid
Sends the frame if its VLAN is
carried on the port. The frame is
sent with the VLAN tag removed
or intact depending on your
configuration with the port
hybrid vlan command. This is
true of the PVID.
Assigning an access port to a VLAN
You can assign an access port to a VLAN in VLAN view or interface view (including Ethernet interface
view and Layer 2 aggregate interface view).
To assign one or multiple access ports to a VLAN in VLAN view:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter VLAN view.
vlan vlan-id
If the specified VLAN does not exist, this
command creates the VLAN first.
3.
Assign one or a group of
access ports to the VLAN.
port interface-list
By default, all ports belong to VLAN 1.
To assign an access port in interface view to a VLAN:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
- H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS H3C SecBlade LB Cards H3C SecPath L1000-A Load Balancer