Enabling embedded rp, Configuring c-rp timers globally – H3C Technologies H3C SecPath F1000-E User Manual
Page 880
855
NOTE:
•
When you configure a C-RP, ensure a relatively large bandwidth between this C-RP and the other
devices in the IPv6 PIM-SM domain.
•
An RP can serve multiple IPv6 multicast groups or all IPv6 multicast groups. Only one RP can forward
IPv6 multicast traffic for an IPv6 multicast group at a moment.
Enabling embedded RP
With the embedded RP feature enabled, the router can resolve the RP address directly from the IPv6
multicast group address of an IPv6 multicast packets. This RP can replace the statically configured RP or
the RP dynamically calculated based on the BSR mechanism. Thus, the DR does not need to know the RP
address beforehand.
Perform this configuration on all routers in the IPv6 PIM-SM domain.
To enable embedded RP:
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter IPv6 PIM view.
pim ipv6
N/A
3.
Enable embedded RP.
embedded-rp [ acl6-number ]
Optional.
By default, embedded RP is
enabled for IPv6 multicast groups
in the default embedded RP
address scopes.
NOTE:
The default embedded RP address scopes are FF7x::/12 and FFFx::/12. Here "x" refers to any legal
address scope. For more information about the Scope field, see
Appendix Protocol References.
Configuring C-RP timers globally
To enable the BSR to distribute the RP-set information within the IPv6 PIM-SM domain, C-RPs must
periodically send C-RP-Adv messages to the BSR. The BSR learns the RP-set information from the received
messages, and encapsulates its own IPv6 address together with the RP-set information in its bootstrap
messages. The BSR then floods the bootstrap messages to all IPv6 routers in the network.
Each C-RP encapsulates a timeout value in its C-RP-Adv messages. After receiving a C-RP-Adv message,
the BSR obtains this timeout value and starts a C-RP timeout timer. If the BSR fails to obtain a subsequent
C-RP-Adv message from the C-RP when the timer times out, the BSR assumes the C-RP to have expired or
become unreachable.
You must configure the C-RP timers on C-RP routers.
To configure C-RP timers globally:
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter IPv6 PIM view.
pim ipv6
N/A
3.
Configure the C-RP-Adv
interval.
c-rp advertisement-interval interval
Optional.
60 seconds by default.
- H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS H3C SecBlade LB Cards H3C SecPath L1000-A Load Balancer