beautypg.com

Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 88

background image

4.3 Motion Parameter Lists

4.3.2 Setting Parameter List

4-12

OL

36

Straight Line
Acceleration/
Acceleration Time
Constant

Units depends on the setting of OW

03, bits 4 to 7 (Accelera-

tion/Deceleration Degree Unit Selection).

Yes

Yes

4.4.2 ( 23 )

OL

38

Straight Line
Deceleration/
Deceleration Time
Constant

Units depends on the setting of OW

03, bits 4 to 7 (Accelera-

tion/Deceleration Degree Unit Selection).

Yes

Yes

OW

3A Filter Time Constant

1 = 0.1 ms

Yes

Yes

4.4.2 ( 24 )

OW

3B

Bias Speed for Expo-
nential Acceleration/
Deceleration Filter

Unit is according to OW

03, bits 0 to 3 (Speed Unit

Selection).

Yes

OW

3C

Zero Point Return
Method

0: DEC1 + C (DEC1 and C-Phase)
1: ZERO (Zero signal)
2: DEC1 + ZERO (DEC1 and ZERO Signal)
3: C (C-pulse)

Yes

4.4.2 ( 25 )

4 to 10: Reserved for system use.

11: C Pulse Only
12: POT & C Pulse
13: POT Only
14: HOME LS & C Pulse
15: HOME Only

Yes

16: NOT & C Pulse
17: NOT Only
18: INPUT & C Pulse
19: INPUT Only

Yes

OW

3D

Width of Starting
Point Position Output 1 = 1 reference unit

Yes

Yes

OL

3E

Approach Speed

Unit is according to OW

03, bits 0 to 3

(Speed Unit Selection).

Yes

OL

40

Creep Rate

Unit is according to OW

03, bits 0 to 3

(Speed Unit Selection).

Yes

OL

42

Zero Point Return
Travel Distance

1 = 1 reference unit

Yes

OL

44

Step Travel Distance 1 = 1 reference unit

Yes

Yes 4.4.2 ( 26 )

OL

46

External Positioning
Final Travel Distance 1 = 1 reference unit

Yes

4.4.2 ( 27 )

OL

48

Zero Point Position in
Machine Coordinate
Offset

1 = 1 reference unit

Yes

Yes

4.4.2 ( 28 )

OL

4A

Work Coordinate
System Offset

1 = 1 reference unit

Yes

Yes

OL

4C

Number of POSMAX
Turns Presetting
Data

1 = 1 turn

Invalid for liner type

Yes

Yes

OW

4E

Servo User Monitor
Setting

Bits 0 to 3: Monitor 1 (Cannot be set.)
Bits 4 to 7: Monitor 2
Bits 8 to B: Monitor 3 (Cannot be set.)
Bits C to F: Monitor 4

Yes

4.4.2 ( 29 )

OW

4F

Servo Driver Alarm
Monitor No.

Set the number of the alarm to monitor.

Yes

4.4.2 ( 30 )

OW

50

Servo Driver User
Constant No.
(SERVOPACK
parameter No. for
motion command)

Set the number of the SERVOPACK parameter.

Yes

(cont’d)

Register No.

Name

Contents

SVB SVR Reference