background image

11.1 Controlling Vertical Axes

11.1.4 Connections to

Σ-I Series SGD SERVOPACK

11-7

Utility Functions

11.1.4 Connections to

Σ-I Series SGD SERVOPACK

( 1 ) Brake ON and OFF Circuit Example

A circuit is configured to turn the brake ON and OFF using the /BK contact output signal from the SERVOPACK and a
brake power supply. The standard connections are shown in the following diagram.

* 1. Brake control relay contact
* 2. There are 200-V and 100-V brake power supplies.

R

T

U

V

W

2CN

1

2

3

4

5

6

Power supply

BK-RY

White

Red

Black

AC

DC

Brake power supply

*2

SGD or SGDA SERVOPACK

Servomotor with a brake

*1

BK-RY

+24 V

-7

-10

/BK

SG-COM

1CN

M

BK

PG

50 mA
max.

Blue or
yellow