beautypg.com

2 ) over range parameter number – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 135

background image

4.4 MP2000 Series Machine Controller Parameter Details

4.4.3 Motion Monitoring Parameter Details

4-59

Motion Parameters

( 2 ) Over Range Parameter Number

IW

01

Parameter Number When Range Over is Generated

Range

Unit

0 to 65535

Description

Stores the number of a parameter set outside the setting range.

• Setting parameters: 0 or higher
• Fixed Parameters: 1000 or higher

This parameter stores the number of the setting or fixed parameter that exceeds the setting range either individually or in
combination with the settings of other parameters.
When motion fixed parameters are used, the parameter stores the parameter number plus 1000.

R