Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 353

9.4 Absolute Position Detection for Infinite Length Axes
9.4.2 Parameter Settings for Simple Absolute Infinite Length Position Control
9-16
( 3 ) SERVOPACK Parameters for Absolute Position Detection
SERVOPACK
Model
Parameter
Name
Setting Range
Units
Reference
Caution
Σ-III
and
Σ-V Series
(SGDS-
1
,
SGDV-
)
Pn000.0
Direction Selection
0: Sets counterclockwise (CCW)
rotation as forward direction.
1: Sets clockwise (CW) rotation as
forward direction (reverse rotation
mode).
−
−
−
Pn205
Multiturn Limit Setting
0 to 65535
Rev
9.4.2 ( 4 ) [ c ]
Pn002.2
Absolute Encoder Usage
0: Uses absolute encoder as an abso-
lute encoder.
1: Uses absolute encoder as an incre-
mental encoder.
−
9.4.2 ( 4 ) [ a ]
Σ-II
Series
(SGDH-
E
+
NS100, NS115)
Pn000.0
Direction Selection
0: Sets counterclockwise (CCW)
rotation as forward direction.
1: Sets clockwise (CW) rotation as
forward direction (reverse rotation
mode).
−
−
−
Pn205
Multiturn Limit Setting
0 to 65535
Rev
9.4.2 ( 4 ) [ c ]
Pn002.2
Absolute Encoder Usage
0: Uses absolute encoder as an abso-
lute encoder.
1: Uses absolute encoder as an incre-
mental encoder.
−
9.4.2 ( 4 ) [ a ]
Σ-I
Series
(SGD-
N,
SGDB-
AN)
Cn-0001,
Bit E
Encoder Type
0: Incremental encoder
1: Absolute encoder
−
9.4.2 ( 4 ) [ a ]
−
Cn-0002,
Bit 0
Rotation Direction
Selection
0: Sets counterclockwise (CCW)
rotation as forward rotation.
1: Sets clockwise (CW) rotation as
forward rotation (reverse rotation
mode).
−
−
−