background image

7.2 Motions After Switching Motion Commands

7.2.2 Switching from EX_POSING

7-10

7.2.2 Switching from EX_POSING

Switched From

Switched To

Operation

EX_POSING

NOP

EX_POSING will switch to NOP when the axis stops after deceleration.

POSING

09, bit 5 = 0)>

EX_POSING will switch to POSING when the axis stops after deceleration.

Incremental value = Target position

− IL

14 (DPOS)

OL

1C = OL

1C + Incremental value

Any change in the Position Reference Setting (OL

1C) during deceleration

will be ignored.

09, bit 5 = 1)>

EX_POSING will immediately switch to POSING, and the moving amount stored in the
acceleration/deceleration filter will be maintained.

The set value of the Position Reference Setting (OL

1C) will be:

OL

1C = Target position

EX_POSING

The EX_POSING operation will continue.

EX_POSING

Cancelled

EX_POSING

operation

EX_POSING

NOP

EX_POSING

NOP

Motion command
Motion command

response

Cancelled

EX_POSING

operation

EX_POSING

EX_POSING

POSING

EX_POSING

POSING

POSING

Motion command

Motion command

response

EX_POSING

Cancelled

EX_POSING

operation

EX_POSING

POSING

EX_POSING

POSING

The speed will smoothly change.

(The speed at the time the motion command

is switched will increase/decrease until it

reaches the target speed of POSING.)

The acceleration/deceleration filter will

remain valid.

POSING

Motion command
Motion command

response