2 switching from ex_posing – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 280

7.2 Motions After Switching Motion Commands
7.2.2 Switching from EX_POSING
7-10
7.2.2 Switching from EX_POSING
Switched From
Switched To
Operation
EX_POSING
NOP
EX_POSING will switch to NOP when the axis stops after deceleration.
POSING
09, bit 5 = 0)> EX_POSING will switch to POSING when the axis stops after deceleration. Incremental value = Target position − IL 14 (DPOS) OL 1C = OL 1C + Incremental value Any change in the Position Reference Setting (OL 1C) during deceleration will be ignored. 09, bit 5 = 1)> EX_POSING will immediately switch to POSING, and the moving amount stored in the The set value of the Position Reference Setting (OL 1C) will be: OL 1C = Target position EX_POSING The EX_POSING operation will continue. EX_POSING Cancelled EX_POSING operation EX_POSING NOP EX_POSING NOP Motion command response Cancelled EX_POSING operation EX_POSING EX_POSING POSING EX_POSING POSING POSING Motion command Motion command response EX_POSING Cancelled EX_POSING operation EX_POSING POSING EX_POSING POSING The speed will smoothly change. (The speed at the time the motion command is switched will increase/decrease until it reaches the target speed of POSING.) The acceleration/deceleration filter will remain valid. POSING Motion command response
acceleration/deceleration filter will be maintained.
Motion command
Motion command