beautypg.com

Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 498

background image

Appendix B Settings When Connecting MECHATROLINK Compatible I/O Modules, MYVIS, and MP940

B.2 I/O Register Configuration

A-9

Appendices

( 10 ) 120EHC21140 and JEPMC-PL2900 (Counter with Preset Function)

For counters with the preset function, the first two words are reserved by the system, and various settings are
required for outputs. Refer to Chapter 5 Reversible Counter with Preset Function and Chapter 6 Pulse Output Mod-
ule
of Machine Controller MP900/MP2000 Series Distributed I/O Module User’s Manual for MECHATROLINK (man-
ual number SIE-C887-5.1) for details.

( 11 ) 120MMB20230 and JEPMC-PL2910 (Pulse MC)

For pulse output modules, the first two words are reserved by the system, and various settings are required for out-
puts. Refer to Chapter 5 Reversible Counter with Preset Function and Chapter 6 Pulse Output Module of Machine
Controller MP900/MP2000 Series Distributed I/O Module User’s Manual for MECHATROLINK
(manual number SIE-
C887-5.1) for details.

( 12 ) MP940 (Machine Controller)

Command Data

Response Data

OW

Scan
counter

High-speed/
Low-speed
control data
(8 words)

IW

High-speed/
Low-speed
control data
(7 words)

OW

+1

Not used

IW

+1

OW

+2

Output coil

IW

+2 Input relay

OW

+3

Output coil

IW

+3 Input register

OW

+4

Output register

IW

+4 Input register

OW

+5

Output register

IW

+5 Input register

OW

+6

Output register

IW

+6 Input register

OW

+7

Output register

Command Data

Response Data

OW

Scan
counter

High-speed/
Low-speed
control data
(8 words)

IW

High-speed/
Low-speed
control data
(8 words)

OW

+1 Not used

IW

+1

OW

+2 Output coil

IW

+2 Input relay

OW

+3 Output coil

IW

+3 Input register

OW

+4 Output register

IW

+4 Input register

OW

+5 Output register

IW

+5 Input register

OW

+6 Output register

IW

+6 Input register

OW

+7 Output register

IW

+7 Input register

Command

Data

Response

Data

OW

High-speed/
Low-speed
control data
(8 words)

IW

High-speed/
Low-speed
control data
(8 words)

OW

+1

IW

+1

OW

+2

IW

+2

OW

+3

IW

+3

OW

+4

IW

+4

OW

+5

IW

+5

OW

+6

IW

+6

OW

+7

IW

+7