6.2 Motion Command Details

6.2.2 Latch Target Positioning (EX_POSING) (External Positioning)

6-11

Motion Commands

6.2.2 Latch Target Positioning (EX_POSING) (External Positioning)

The EX_POSING command positions the axis to the target position using the specified target position and speed.
Parameters related to acceleration and deceleration are set in advance.
If the external positioning signal turns ON during axis movement, the axis will move the distance specified for the
External Positioning Final Travel Distance from the point at which the external positioning signal turned ON, and then
stop. If the external positioning signal does not turn ON, positioning will be completed to the original target position.

When using an SGDV SERVOPACK, the torque limit can be set and changed during SERVOPACK operation. For
details, refer to Setting and Changing Torque Limit during SGDV SERVOPACK Operations of 4.4.2 ( 12 ) and Pre-
cautions
of 6.2.1 ( 3 ). When using a DC Power Input

Σ-V Series SERVOPACK (Model: SGDV-

E1

), also

refer to 11.7.4 Motion Command Operation for External Latches with DC Power Input

Σ

-V-series SERVOPACKs.

For more information on the maximum allowable value for acceleration and deceleration, refer to Changing the max-
imum value of acceleration and deceleration for SGDV SERVOPACKs
of 4.4.2 ( 23 ).

( 1 ) Executing/Operating Procedure

1.

Check to see if all the following conditions are satisfied.

* This condition is a basic execution condition. Refer to Chapter 7 Switching Commands during Execution when

changing the command that is being executed to an EX_POSING command.

2.

Set the following motion setting parameters.

External Positioning Final Travel Distance: OL

46

External Positioning Signal Setting: OW

04

Speed Reference Setting: OL

10

Filter Type Selection: OW

03, bits 8 to B

Speed Loop P/PI Switch: OW

01

Position Reference Setting: OL

1C

The Speed Reference

Setting

can be changed during operation.

An override of between 0% to 327.67% can be set for the speed reference.
A latch zone can be set as long as it is supported by the SERVOPACK being used.

3.

Set OW

08 to 2 to execute the EX_POSING motion command to use the preceding settings in the

same scan.

4.

Turn ON the external positioning signal.

The axis will be moved the External Positioning Final Travel Move Distance and decelerate to a stop.
IW

09, bit 8 will turn ON when the axis stops and external positioning has been completed.

R

No.

Execution Conditions

Confirmation Method

1

There are no alarms.

Both IL

02 and IL

04 are 0.

2

The Servo ON condition.

IW

00, bit 1 is ON.

3

Motion command execution has been completed.

*

IW

08 is 0 and IW

09, bit 0 is OFF.