12 change filter type (chg_filter), 1 ) executing/operating procedure, 2 ) holding and aborting – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 221: 3 ) related parameters

6.2 Motion Command Details
6.2.12 Change Filter Type (CHG_FILTER)
6-60
6.2.12 Change Filter Type (CHG_FILTER)
The CHG_FILTER command enables the current setting of the Filter Type Selection (motion setting parameter
OW
03, bits 8 to B) for execution of the following motion commands with the movement: POSING, EX_POSING,
ZRET, INTERPOLATE, LATCH, FEED, and STEP.
Always execute the CHG_FILTER command after changing the setting of OW
03, bits 8 to B. If this is not exe-
cuted, the change in the Filter Type setting will not be validated.
( 1 ) Executing/Operating Procedure
1.
Check to see if all the following conditions are satisfied.
2.
Set OW
08 to 13 to execute the CHG_FILTER motion command.
The Filter Type Selection (motion setting parameter OW
03 Bit8 to B) will be enabled.
IW
08 will be 13 during command execution.
IW
09, bit 0 will turn ON during the command processing and will turn OFF when the command processing
has been completed.
3.
Set OW
08 to 0 to execute the NOP motion command and then complete the change of the filter
type.
( 2 ) Holding and Aborting
The Holds a Command bit (OW
09, bit 0) and the Interrupt a Command bit (OW
09, bit 1) cannot be used.
( 3 ) Related Parameters
[ a ] Setting Parameters
[ b ] Monitoring Parameters
No.
Execution Conditions
Confirmation Method
1
There are no alarms.
Both IL
02 and IL
04 are 0.
2
Pulse distribution has been completed for the SERVOPACK.
IW
0C, bit 0 is ON.
3
Motion command execution has been completed.
IW
08 is 0 and IW
09, bit 0 is OFF.
Parameter
Name
Setting
OW
03
Function Setting 1
Set the speed unit, acceleration/deceleration units, and filter type.
OW
08
Motion Command
The filter type is changed when this parameter is set to 13.
OW
09
Bit 0
Holds a Command
This parameter is ignored for CHG_FILTER command.
OW
09
Bit 1
Interrupt a Command
This parameter is ignored for CHG_FILTER command.
Parameter
Name
Monitor Contents
IL
02
Warning
Stores the most current warning.
IL
04
Alarm
Stores the most current alarm.
IW
08
Motion Command
Response Code
Indicates the motion command that is being executed.
The response code will be 13 during CHG_FILTER command execution.
IW
09
Bit 0
Command Execution
Flag
Turns ON during CHG_FILTER command execution and turns OFF when execution
has been completed.
IW
09
Bit 1
Command Hold
Completed
Always OFF for CHG_FILTER command.
IW
09
Bit 3
Command Error
Completed Status
Turns ON if an error occurs during CHG_FILTER command execution. Turns OFF
when another command is executed.
IW
09
Bit 8
Command Execution
Completed
Turns ON when CHG_FILTER command execution has been completed.