beautypg.com

Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 406

background image

10.4 Motion Parameter Details

10.4.3 Monitoring Parameter List

10-42

IW

40

User Constant
Reading Data 3

Range: 0 to 65535

Displays the value read out by executing the com-
mand Read User Constant. Valid when Inverter User
Constant Number Size (OW

3D) = 3 or 4.

IW

41

User Constant
Reading Data 4

Range: 0 to 65535

Displays the value read out by executing the com-
mand Read User Constant. Valid when Inverter User
Constant Number Size (OW

3D) = 4.

IW

42

Auxiliary Inverter User Constant Number

Range: 0 to 65535

Displays the auxiliary inverter user constant number
set for the subcommand Read User Constant or Write
User Constant.

IW

43

Reserved by the system.

IW

44

Auxiliary User Constant
Reading Data 1

Range: 0 to 65535

Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW

43) = 1

to 4.

IW

45

Auxiliary User Constant
Reading Data 2

Range: 0 to 65535

Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW

43) = 2

to 4.

IW

46

Auxiliary User Constant
Reading Data 3

Range: 0 to 65535

Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW

43) = 3

or 4.

IW

47

Auxiliary User Constant
Reading Data 4

Range: 0 to 65535

Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW

43) = 4.

IL

48

Fixed Parameter Monitor

Displays the fixed parameter value read out by execut-
ing the subcommand Read Fixed Parameters.

IW

4A

to

IW

4F

Reserved by the system.

IW

50

to

IW

5F

Inverter/Type

Displays the connected Inverter model.

IW

60

to

IW

67

Inverter/Software Version (Communication Board)

Displays the software version number of the optional
communication board of the connected Inverter.

IW

68

to

IW

6F

Inverter/Software Version (Main)

Displays the software version number of the connected
Inverter.

IW

70

Transmission Reference
Input Data 0

Range: 0 to FFFFH

Displays the 1st word of the response data to the com-
mand Transmission Reference.

IW

71

Transmission Reference
Input Data 1

Range: 0 to FFFFH

Displays the 2nd word of the response data to the
command Transmission Reference.

IW

72

Transmission Reference
Input Data 2

Range: 0 to FFFFH

Displays the 3rd word of the response data to the
command Transmission Reference.

IW

73

Transmission Reference
Input Data 3

Range: 0 to FFFFH

Displays the 4th word of the response data to the
command Transmission Reference.

IW

74

Transmission Reference
Input Data 4

Range: 0 to FFFFH

Displays the 5th word of the response data to the
command Transmission Reference.

Register No.

Name

Contents