Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 406

10.4 Motion Parameter Details
10.4.3 Monitoring Parameter List
10-42
IW
40
User Constant
Reading Data 3
Range: 0 to 65535
Displays the value read out by executing the com-
mand Read User Constant. Valid when Inverter User
Constant Number Size (OW
3D) = 3 or 4.
IW
41
User Constant
Reading Data 4
Range: 0 to 65535
Displays the value read out by executing the com-
mand Read User Constant. Valid when Inverter User
Constant Number Size (OW
3D) = 4.
IW
42
Auxiliary Inverter User Constant Number
Range: 0 to 65535
Displays the auxiliary inverter user constant number
set for the subcommand Read User Constant or Write
User Constant.
IW
43
−
Reserved by the system.
IW
44
Auxiliary User Constant
Reading Data 1
Range: 0 to 65535
Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW
43) = 1
to 4.
IW
45
Auxiliary User Constant
Reading Data 2
Range: 0 to 65535
Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW
43) = 2
to 4.
IW
46
Auxiliary User Constant
Reading Data 3
Range: 0 to 65535
Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW
43) = 3
or 4.
IW
47
Auxiliary User Constant
Reading Data 4
Range: 0 to 65535
Displays the value read out by executing the subcom-
mand Read User Constant. Valid when Auxiliary
Inverter User Constant Number Size (OW
43) = 4.
IL
48
Fixed Parameter Monitor
Displays the fixed parameter value read out by execut-
ing the subcommand Read Fixed Parameters.
IW
4A
to
IW
4F
−
Reserved by the system.
IW
50
to
IW
5F
Inverter/Type
Displays the connected Inverter model.
IW
60
to
IW
67
Inverter/Software Version (Communication Board)
Displays the software version number of the optional
communication board of the connected Inverter.
IW
68
to
IW
6F
Inverter/Software Version (Main)
Displays the software version number of the connected
Inverter.
IW
70
Transmission Reference
Input Data 0
Range: 0 to FFFFH
Displays the 1st word of the response data to the com-
mand Transmission Reference.
IW
71
Transmission Reference
Input Data 1
Range: 0 to FFFFH
Displays the 2nd word of the response data to the
command Transmission Reference.
IW
72
Transmission Reference
Input Data 2
Range: 0 to FFFFH
Displays the 3rd word of the response data to the
command Transmission Reference.
IW
73
Transmission Reference
Input Data 3
Range: 0 to FFFFH
Displays the 4th word of the response data to the
command Transmission Reference.
IW
74
Transmission Reference
Input Data 4
Range: 0 to FFFFH
Displays the 5th word of the response data to the
command Transmission Reference.
Register No.
Name
Contents