4.3 Motion Parameter Lists

4.3.1 Fixed Parameter List

4-7

Motion Parameters

18 to 29

Reserved for system use.

30

Encoder Selection

0: Incremental encoder
1: Absolute encoder
2: Absolute encoder (Incremental encoder is used.)
3: Reserved (External encoder)

Yes

4.4.1 ( 8 )

31 to 33

Reserved for system use.

34

Rated Motor Speed (Rotary
Motor)

1 = 1 min

-1

Yes

Yes

4.4.1 ( 9 )

Rated Speed (Linear Motor)

1 = 0.1 m/s, 0.1 mm/s

Yes

Yes

36

Number of Pulses per Motor
Rotation (Rotary Motor)

1 = 1 pulse/rev
Set the value after multiplication.

Yes

Yes

Number of Pulses per Linear
Scale Pitch (Linear Motor)

1 = 1 pulse/scale pitch

Yes

Yes

38

Maximum Number of Abso-
lute Encoder Turns Rotation

1 = 1 rev

Set to 0 when a direct drive motor is being used.
Invalid for linear type

Yes

40 to 41

Reserved for system use.

42

Feedback Speed Movement
Averaging Time Constant

1 = 1 ms

Yes

Yes

4.4.1 ( 9 )

(cont’d)

No.

Name

Contents

SVB SVR

Reference