beautypg.com

5 ) timing charts, A ] normal execution [ b ] executed when aborted – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 248

background image

6.2 Motion Command Details

6.2.23 Torque /Thrust Reference (TRQ)

6-87

Motion Commands

( 5 ) Timing Charts

[ a ] Normal Execution

[ b ] Executed when Aborted

IW

09

Bit 8

Command Execution
Completed

Always OFF for TRQ command.

IW

0C

Bit 0

Discharging Complet-
ed

Turns ON when pulse distribution has been completed for the move command.
Turns OFF during execution of a move command.

IW

0C

Bit 1

Positioning
Completed

Turns ON when pulse distribution has been completed and the current position is
within the width of Positioning Completion. OFF in all other cases.

IW

0C

Bit 3

NEAR Position

The operation of this bit depends on the setting NEAR Signal Output Width (set-
ting parameter OL

20).

OL

20 = 0: Turns ON when pulse distribution has been completed (DEN =

ON). Otherwise, it turns OFF.

OL

20

0: Turns ON when the absolute value of the difference between

MPOS (IL

12) and APOS (IL

16) is less than the

NEAR Signal Output Width, even if pulse distribution has not
been completed.
OFF in all other cases.

(cont’d)

Parameter

Name

Monitor Contents

SVR

R

R

R

R

OW

08 = 24 (TRQ)

IW

08 = 24 (TRQ)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

IW

0C, bit 0 (DEN)

1 scan

IW

0C, bit 1 (POSCOMP)

1 scan

OW

09, bit 1 (ABORT)

Torque Control Mode

Position Control Mode

OW

08 = 24 (TRQ)

IW

08 = 24 (TRQ)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

IW

0C, bit 0 (DEN)